“DATA ERROR” is displayed in place of a parameter value
The ECU is sending a message that there is a data error
with this parameter. Or (PV101 only) FUEL LEVEL has
been selected for display, ANALOG INPUT has been set to
FUEL LEVEL, but no Murphy Fuel Sender has been
connected to the analog input.
One of the 4-UP quadrants is empty
No parameter has been selected for display in this
quadrant.
Display is not readable, either very dim or very dark
The LCD contrast may have been over or under adjusted.
Press and hold the MENU key for approximately 5
seconds. This will reset the LCD contrast setting to factory
default.