00-02-0614
03-05-08
Section 15
LS200, LS200N,
LS200NDVOR Series and
L1100 Liquid Level Switches
Installation and Operations Manual
Vista de pagina 0
1 2 3 4 5 6 ... 21 22

Indice de contenidos

Pagina 1 - L1100 Liquid Level Switches

00-02-0614 03-05-08 Section 15 LS200, LS200N, LS200NDVOR Series and L1100 Liquid Level Switches Installation and Operations Manual

Pagina 2

Section 15 00-02-0614 03-05-08 - 6 - Installation and Adjustment for Pneumatic Models 1. All pneumatic models operate on the vent principle. Th

Pagina 3 - Table of Contents

Section 15 00-02-0614 03-05-08 - 7 - Trip Cam Operating Lever Orientation The LS200 series level switches are shipped with the trip cam orientatio

Pagina 4

Section 15 00-02-0614 03-05-08 - 8 - Replacing and Installing the DVO Assembly NOTE: When replacing/installing the DVO assembly, tubing and fitti

Pagina 5 - Product Information

Section 15 00-02-0614 03-05-08 - 9 - Instructions 1. Block off and bleed the instrument gas pressure supply to the LS200NDVO/DVOR. 2. Remove the

Pagina 6 - LS200NDVOR

Section 15 00-02-0614 03-05-08 - 10 - CAUTION: Ensure that the actuator arm is not bent during reassembly. 14. Connect to the inlet, outlet,

Pagina 7 - LS200NDVO

Section 15 00-02-0614 03-05-08 - 11 - Electrical Replacement Parts CAUTION: LS200 Series parts are not interchangeable with other Murphy liquid

Pagina 8

Section 15 00-02-0614 03-05-08 - 12 - L1100 15000893: BUOYGLAS™ float 15000937: Stainless steel float 15000124: SPDT snaps switch assembly 1500

Pagina 9

Section 15 00-02-0614 03-05-08 - 13 - 15051098: External Float Chamber Operating pressure: 2000 psi (13.8 MPa) [138 bar] Operating temperature:

Pagina 10

Section 15 00-02-0614 03-05-08 - 14 - 15000478: Float Shaft Extension for the LS200 CAUTION: Not interchangeable with L1200 parts. Use of 1” e

Pagina 11

Section 15 00-02-0614 03-05-08 - 15 - The Murphy Gas Compressor Scrubber Level System (SLS)

Pagina 12 - Tools Needed

In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any

Pagina 13 - Instructions

Section 15 00-02-0614 03-05-08 - 16 - Specifications All Models • Body: Nickel plated steel; optional 316 stainless steel (meets NACE standard MR

Pagina 14

Section 15 00-02-0614 03-05-08 - 17 - MURPHY, the Murphy logo, and Liquid level Switches (LS) are registered and/or common law trademarks of Murph

Pagina 16 - Accessories

Table of Contents Product Information...

Pagina 17

(THIS PAGE INTENTIONALLY LEFT BLANK)

Pagina 18

Section 15 00-02-0614 03-05-08 - 1 - Product Information Features • Designed for harsh gas compressor scrubber applications • 304 stainless stee

Pagina 19 - Section 15 00-02-0614

Section 15 00-02-0614 03-05-08 - 2 - LS200NDVOR LS200NDVOR is a float-activated, pneumatic-vent level device used to operate dump valves or simila

Pagina 20 - Specifications

Section 15 00-02-0614 03-05-08 - 3 - LS200NDVO Pneumatic level switch with snap action Dump Valve Operator (DVO) without the pressure regulator fo

Pagina 21 - 03-05-08 - 17

Section 15 00-02-0614 03-05-08 - 4 - Pressure Vessel Installation: LS200, LS200N and L1100 Direct Installation into the Wall of the Pressure Vess

Pagina 22

Section 15 00-02-0614 03-05-08 - 5 - Installation with a Weld Collar 1. The weld collar, P/N 15050375, must be welded into the wall of the pressu